HP Data Protector软件“the daemon is probable no runnig”故障

一台装有HP Data Protector备份软件的服务器出问题,不能备份,打开桌面上的软件图标后,任意点击一些菜单,都提示“the daemon is probable no runnig ”或者是“interprocess communication problem”,使用omnisv.exe -status查看后,发现rds服务为down,如下:

D:Program FilesOmniBackbin>omnisv -status

ProcName Status [PID]
===============================
rds : Down
crs : Active [664]
mmd : Active [884]
omniinet: Active [712]
Sending of traps disabled.
===============================
Status: At least one of Data Protector relevant processes/services is not running.

使用omnisv -?查看命令帮助,然后使用omnisv.exe -stop将所有服务都停止:

D:Program FilesOmniBackbin>omnisv -stop

ProcName Status [PID]
===============================
rds : Down
crs : Down
mmd : Down
omniinet: Down
Sending of traps disabled.
===============================

再使用start使所有服务都开启:

D:Program FilesOmniBackbin>omnisv -start

ProcName Status [PID]
===============================
rds : Active [1024]
crs : Active [3436]
mmd : Active [1112]
omniinet: Active [2580]
Sending of traps disabled.
===============================

把DP软件关了,再打开后,就可以正常打开所有的菜单了。

hpdp3

hpdp1